Facades & Curtain Walls · Unitized
Unitized Curtain Wall Systems
Unitized curtain walls for high-rise and commercial projects: factory-assembled modules, interface engineering, production sequencing and installation conditions — configured and confirmed per project.
Submit facade drawings for a unitization assessment All Facade Systems

Unitized curtain walls are factory-assembled, glazed and sealed modules, hoisted floor by floor and hung from the building structure. The method trades site labor for factory quality control. Starveil engineers project-specific unitized systems from Foshan, with module coordination, interface detailing and installation sequencing confirmed per project during specification.
Unitized scopes are engineered per building: module dimensions follow your structural grid, framing depths follow site exposure, and the testing route follows your destination market — each value locked at specification with its evidence trail.
01
The Facade That Is Built Before It Arrives
A unitized curtain wall moves the difficult work indoors. Instead of assembling mullions, transoms, gaskets and glass on a scaffold in whatever weather the site provides, the wall is manufactured as complete modules in a factory — framed, glazed, sealed and QC-checked at bench height — then shipped to site and hoisted into position, module by module, floor by floor.
The unit of fabrication becomes the unit of installation. That single shift drives everything else on this page: quality moves indoors, site programs compress, water and air seals are made by trained hands under supervision rather than by rope-access crews on a deadline, and the building gets a facade whose condition was verified before it ever left the ground.
02
Where Unitized Earns Its Place
- High-rise residential and commercial towers, where repetition of module types rewards factory setup and site speed.
- Hotels and institutional projects, where envelope quality expectations and program discipline run high.
- Repetitive facades with variation — punched bands, stacked ribbon glazing — where the factory absorbs repetition the site would otherwise pay for twice.
- Sites with constrained logistics, where shorter crane windows and smaller on-site crews change the economics decisively.
Low-rise, heavily bespoke facades with little repetition may point toward stick construction — that route is evaluated per project, and we will tell you when it does. A supplier who only ever recommends one method is recommending their catalogue, not your building.

03
Unitized vs Stick: The Decision in One Table
| Unitized | Stick | |
|---|---|---|
| Where the wall is built | Factory, at bench height | On site, floor by floor |
| Sealing quality | Sealed and tested indoors before shipping | Dependent on site conditions and crews |
| Site program | Shorter — modules arrive ready to hang | Longer — assembly follows the facade trades |
| Crane and logistics | Sustained hoisting plan for finished modules | Material staging and on-site fabrication space |
| Repetition benefit | Strong — module types amortize tooling and setup | Weak — each opening is its own event |
| Typical fit | High-rise, repetitive, program-driven | Low-rise, bespoke, low-module-count |
Most projects read this table and recognize themselves in one column within a minute. The projects that need a conversation are the ones with a foot in each — and that conversation is exactly what the specification review is for.
04
Module Design Follows Your Structural Grid
Unitized modules are not catalogue sizes; they are derived from your building. Module dimensions follow your structural grid, floor-to-floor heights and slab-edge conditions — typically spanning floor to floor, one module wide, hung from the slab and restrained at the head, with movement joints engineered between modules to absorb live-load deflection, thermal movement and seismic behavior where the site demands it.
This is why unitized projects start with your drawings, not our product list. The grid, the slab edge and the anchorage zone determine the module family; the wind exposure of the specific site determines the framing depths and glazing makeup; the market you are building in determines the testing and certification route. Every one of those values is confirmed per project during specification, because a facade performance figure that is not attached to a specific configuration is a marketing number, not an engineering one.
05
Interface Engineering: Where Unitized Projects Are Won
The module is the visible product; the interfaces are the actual work. A unitized envelope meets the building at every slab edge, anchors into structure, and neighbors every other trade that touches the perimeter — and each of those meetings is a designed detail, not a site negotiation.
- Anchorage and adjustment — bracket zones sized to absorb fabrication and structural tolerances before they reach the module.
- Inter-module joints — gasket and seal strategy that keeps weather out at every module boundary while allowing the building to move.
- Slab-edge interfaces — spandrel, insulation and fire-barrier coordination with your floor construction.
- Perimeter neighbors — the wall’s junctions with windows where applicable, louvres, entrance systems and roof interfaces, coordinated at drawing stage.
Our engineering team scopes these interfaces with your design team during specification. The alternative — deciding them on the scaffold — is where unitized budgets go to die.
06
Production and QC: The Reason the Method Exists
Module family engineering
your grid and exposure conditions resolved into a module design and interface detail set.
Prototype module
first-article assembly reviewed against drawings before the line commits.
Line production
framing, glazing and sealing at workstations, with in-process QC at defined hold points — including water-testing of sample modules per project requirements.
Packaging and logistics
modules shipped in sequence, packed and braced for the route, in installation order rather than container convenience.
Installation coordination
hoisting plans, sequencing and site tolerances agreed with your erection contractor before the first module leaves the factory.
Sequencing deserves its own sentence: unitized projects ship in installation order. A factory that loads containers by packing convenience and a site that needs floor seven first have a conversation to have — early.

07
The Evidence Boundary
Starveil engineers unitized systems from Foshan with in-house technical coordination and manufacturing network execution — the three-tier engineering model on our engineering page describes exactly how. We document module engineering, the identified fabricator, hold-point QC and project-specific configuration. Facade performance testing and approval evidence follow the proposed system and destination project. The aluminum window and door certificates held by our partners for the United States, Canada and Australia do not certify a unitized curtain wall; facade evidence is submitted separately.
08
Related Project Evidence
Commercial and mixed-use envelope scopes, including facade and curtain wall packages coordinated with windows and doors as one building envelope, are documented in our projects section.
FAQ
Frequently Asked Questions
What is the difference between unitized and stick curtain wall?
Unitized modules are factory-assembled, glazed and sealed, then hoisted into place; stick systems are assembled piece by piece on site. See the comparison table above — the drivers are repetition, program and site logistics.
Can you quote performance values for your unitized systems?
Not as catalogue figures. Water tightness, air tightness and structural behavior belong to a specific module design, glazing makeup and market standard — confirmed per project during specification, with test references supplied.
Do you handle stick curtain wall projects too?
Stick is evaluated per project — for low-repetition, low-rise scopes it can be the better route. We will say so when it is, rather than bend your building to one method.
How early should unitized engineering start?
Before facade tender, ideally at concept or schematic stage — the module design follows your structural grid, and grid decisions made without the facade at the table constrain everything downstream.
Who installs the modules?
Modules are typically erected by your facade contractor under a coordinated hoisting and sequencing plan we agree before production. Installation interfaces are engineered, not improvised.
Can unitized walls combine with our window and door packages?
Yes — that coordination is one of the method’s strengths, and the building envelope package page describes how windows, doors and facade scopes are specified as one system.
Planning a Unitized Envelope?
Send your elevations, typical floor plan and structural grid — even at concept stage. We will assess unitization against your repetition and program, flag the interface conditions your design team should own early, and confirm which performance values will be locked at specification. The assessment is where a facade budget is protected.